AVA5-50, HELIAX® Andrew Virtual Air™ Coaxial Cable, corrugated copper, 7/8 in, black PE jacket

Specifications

Construction Materials 

Jacket Material  PE
Outer Conductor Material  Corrugated copper
Dielectric Material  Foam PE
Flexibility  Standard
Inner Conductor Material  Copper tube
Jacket Color  Black
 

Dimensions 

Nominal Size  7/8 in
Cable Weight  0.30 lb/ft | 0.45 kg/m
Diameter Over Dielectric  24.130 mm | 0.950 in
Diameter Over Jacket  27.991 mm | 1.102 in
Inner Conductor OD  9.4488 mm | 0.3720 in
Outer Conductor OD  25.400 mm | 1.000 in
 

Electrical Specifications 

Cable Impedance  50 ohm ±1 ohm
Capacitance  22.0 pF/ft | 73.0 pF/m
dc Resistance, Inner Conductor  0.410 ohms/kft | 1.435 ohms/km
dc Resistance, Outer Conductor  0.340 ohms/kft | 1.116 ohms/km
dc Test Voltage  6000 V
Inductance  0.184 µH/m | 0.056 µH/ft
Insulation Resistance  100000 Mohms•km
Jacket Spark Test Voltage (rms)  8000 V
Operating Frequency Band  1 – 5000 MHz
Peak Power  91.0 kW
Pulse Reflection  0.50%
Velocity  91%
 

Environmental Specifications 

Installation Temperature  -40 °C to +60 °C (-40 °F to +140 °F)
Operating Temperature  -55 °C to +85 °C (-67 °F to +185 °F)
Storage Temperature  -70 °C to +85 °C (-94 °F to +185 °F)
 

General Specifications 

Brand  HELIAX®
 

Mechanical Specifications 

Bending Moment  19.0 N-m | 14.0 ft lb
Flat Plate Crush Strength  75.0 lb/in
Minimum Bend Radius, Multiple Bends  254.00 mm | 10.00 in
Minimum Bend Radius, Single Bend  127.00 mm | 5.00 in
Number of Bends, minimum  15
Number of Bends, typical  30
Tensile Strength  159 kg | 350 lb
 
 

Standard Conditions 

Attenuation, Ambient Temperature  20 °C | 68 °F
Average Power, Ambient Temperature  40 °C | 104 °F
Average Power, Inner Conductor Temperature  100 °C | 212 °F
 

VSWR

Frequency Band VSWR
806–960 MHz 1.13
1700–2170 MHz 1.13